CN EN

news

How to Choose Insulation Materials for LNG Tanks?

Editor:ZHEJIANG ZHENSHEN INSULATION TECHNOLOGY CORP.LTD. │ Release Time:2026-11-23 

LNG (Liquefied Natural Gas) is typically stored at approximately -162°C. Due to the significant temperature difference between the tank interior and the surrounding environment, external heat continuously enters the tank, increasing the amount of boil-off gas (BOG). Therefore, an LNG tank insulation system must not only minimize heat ingress but also withstand long-term cryogenic conditions and structural changes.

Different sections of an LNG tank have different structural and mechanical requirements. The selection of industrial insulation materials should consider the installation location, low-temperature stability, mechanical properties, recovery capability, and installation conditions.

How to Select Insulation Materials for Different LNG Tank Sections?

In double-wall LNG tanks, the annular space, tank bottom, and roof have different insulation requirements.

Installation LocationCommon Insulation MaterialsKey Considerations
Annular spaceGlass fiber resilient blanket, expanded perliteRecovery performance, uniform filling
Tank bottomCellular glassCompressive strength, dimensional stability
Tank roofGlass fiber insulation, expanded perlite, etc.Weight, thermal performance, installation conditions

Glass fiber resilient blankets are commonly used in the annular space of certain double-wall tank designs and can be combined with expanded perlite. Besides providing thermal insulation, their flexible structure helps accommodate changes in the inner tank wall and cushions lateral pressure from the filling material.

What Properties Should You Consider When Choosing LNG Tank Insulation Materials?

1. Low-Temperature Stability

LNG tanks experience temperature changes during precooling, filling, and operation. Insulation materials must withstand the specified design temperature without becoming brittle, cracking, or losing structural integrity.

When selecting materials, check the low-temperature stability of both the insulation material and its bonding structure. Room-temperature performance alone is not sufficient to determine suitability for cryogenic applications.

2. Thermal Conductivity and Insulation Thickness

Thermal conductivity is an important indicator of insulation performance, but actual results also depend on material thickness, density, and installation quality.

Evaluate thermal conductivity under relevant operating temperatures and determine the required thickness through thermal calculations. Poorly sealed joints, gaps, and uneven coverage can create additional heat transfer paths and reduce overall insulation efficiency.

3. Flexibility and Recovery Performance

These properties are particularly important when selecting insulation for the annular space of double-wall LNG tanks.

The inner tank contracts and expands during precooling and operation. Meanwhile, expanded perlite in the annular space may settle or become compacted over time. Glass fiber resilient blankets provide flexibility and recovery capability, helping cushion lateral pressure from the filling material and accommodate changes in the inner tank wall position.

Material selection should also consider compression recovery, tensile strength, and long-term performance under sustained compression.

4. Moisture Content and Moisture Protection

Moisture entering a cryogenic insulation system may freeze, alter local heat transfer conditions, and affect the stability of the insulation structure.

During procurement, check material moisture content, packaging integrity, and storage requirements. Appropriate moisture protection measures should also be incorporated into the tank design. Fibrous insulation materials cannot replace a dedicated moisture barrier or vapor barrier system.

What Are the Differences Between Common LNG Tank Insulation Materials?

MaterialMain CharacteristicsCommon Applications
Glass Fiber Resilient BlanketFlexible structure with recovery capabilityAnnular space of certain double-wall tanks
Expanded PerliteGranular material suitable for filling large spacesTank annular space
Cellular GlassClosed-cell structure with good compressive strength and moisture resistanceTank bottoms
PIR/PUR FoamLow thermal conductivity; available in boards and pipe sectionsCryogenic pipes and equipment

These materials are not directly interchangeable. Glass fiber resilient blankets mainly provide flexibility and cushioning, while expanded perlite fills the available space. Cellular glass is more suitable for areas requiring higher compressive strength. The final material configuration should follow the tank design.

What Should Be Considered During LNG Tank Insulation Installation?

  • ▪Transportation and Storage: Keep packaging intact and store materials in dry conditions to prevent moisture absorption and compression damage.
  • ▪Pre-Installation Inspection: Check for tears, deformation, and moisture damage before installation.
  • ▪Placement and Filling: Follow design requirements for thickness, joints, and coverage. Avoid gaps and excessive compression.
  • ▪Installation Quality Control: Ensure uniform filling and continuous insulation coverage, with no obvious installation defects.

For glass fiber resilient blankets, particular care should be taken during handling and placement to prevent tearing or localized compression that could affect their recovery performance.

Conclusion

Selecting insulation materials for LNG tanks requires consideration of tank structure, installation location, and operating conditions. For the annular space of double-wall tanks, flexibility, recovery performance, and low-temperature stability are just as important as thermal insulation properties. Matching material characteristics with structural requirements helps improve insulation system reliability and long-term performance.